This article describes the call behavior limitations defined by the radio systems. TRBOnet System Bridge operates within these system-level constraints and does not impose additional restrictions.

1. Group and Private Calls

System Type Group Calls Private Calls Notes
IPSC With or without NAI Voice
CPSS or CPMS NAI Voice only
CapMax / ConnPlus / DEX Limited It is not possible to call to Private ID not registered on controller
Private calls from Capacity Max / Dimetra / Connect Plus to other systems are not possible.
Private calls from others systems to Capacity Max / Dimetra / Connect Plus are possible.

2. Emergency Alerts

Scenario Behavior
IPSC → IPSC (without NAI) Full Emergency Alert (visual + audible) is bridged
All other system combinations Only Emergency Call is bridged (with Emergency attribute) — no visual "Emergency Alert" notification is sent

3. Display Name / Caller Information Behavior

Call Direction NAI in IPSC Receiving Radio Display
IPSC → CPMS ✘  Radio ID of the Subscriber initiated the Bridge
IPSC → CPMS ✔  Radio Name from TRBOnet Radio profile
CPMS → IPSC ✘  Radio ID of the Subscriber initiated the Bridge
CPMS → IPSC ✔  Radio Name from TRBOnet Radio profile
Analog System → CPMS (Quick Call II) N\A Displays "Radio" and plays tones